LLC “SKB Vibration and Resource” Vibration diagnostic instruments
+3806699xxxxx, +3805771xxxxx, Display phones

IDVP.01 Rotor Vibration Measurement Module

Availability:
In stock
Price :
Negotiable
  

Product description

IDVP.01 Vibration Monitoring Module

The IDVP.01 Vibration Monitoring Module (VMM) is designed for non-contact measurement of relative shaft displacement and relative shaft vibration displacement, as well as for monitoring the peak-to-peak value of the relative vibration displacement of rotating parts of industrial equipment (units, machines, and mechanisms).

The IDVP.01 VMM can be used either as a standalone module for measurement, alarm indication, and machinery protection against controlled parameters exceeding preset alarm and trip levels, or as part of the PULS 1.02 monitoring and measurement system, a Process Automation System (PAS), or other industrial automation systems.

Composition of the IDVP.01 Vibration Measurement Module

The IDVP.01 Vibration Monitoring Module (VMM) consists of:

  • a non-contact, single-channel eddy-current primary transducer (probe), model IP-IP;
  • a signal conditioner, model FP-IP.

The IDVP.01 VMM provides the following functions:

  • continuous measurement of the current values of relative shaft displacement and relative shaft vibration displacement of rotating equipment;
  • monitoring and alarm indication for:
    • peak-to-peak relative shaft vibration displacement exceeding preset alarm/trip levels (three levels);
    • vibration jump detection;
    • low-frequency (LF) vibration level exceeding the preset threshold;
  • transmission of measured relative shaft displacement, peak-to-peak relative shaft vibration displacement, as well as the amplitudes and phase angles of the harmonic components of the relative shaft vibration signal via an RS-485 serial interface to external monitoring and visualization systems;
  • indication of primary transducer (probe) faults, including short circuit and open circuit conditions in the communication line between the primary transducer and the signal conditioner;
  • transmission of alarm events and diagnostic information via the RS-485 serial interface to external monitoring and visualization systems;
  • generation of discrete output signals indicating vibration jump events, excessive low-frequency vibration, and peak-to-peak relative shaft vibration displacement reaching preset alarm/trip levels for external alarm systems;
  • generation of a standard 4–20 mA analog current output proportional to the peak-to-peak relative shaft vibration displacement;
  • generation of a 0–3 V analog voltage output proportional to the instantaneous values of relative shaft vibration displacement and relative shaft displacement;
  • automatic compensation for ambient temperature effects (temperature compensation) on measured relative shaft displacement and relative shaft vibration displacement;
  • automatic self-diagnostics and functional integrity monitoring.

Characteristics of the IDVP.01 Vibration Monitoring Module

Parameter Specification
Relative vibration displacement peak-to-peak measurement range, µm 20¹ – 4000²
Relative displacement measurement range, µm 20¹ – 4000²
Frequency measurement range of relative vibration displacement peak-to-peak value, Hz 0.05 – 500³
Reference measurement frequency, Hz 80⁴
Maximum permissible basic relative measurement error of relative vibration displacement peak-to-peak value at the reference frequency, % ±5
Amplitude-frequency response (AFR) non-uniformity, max, % ±3
Maximum permissible basic relative measurement error of relative displacement, % ±5
Nominal conversion factor of relative vibration displacement/displacement, mV/µm 0.5⁵
Maximum deviation of the actual conversion factor value of relative vibration displacement at the reference frequency, max, % ±5
Maximum deviation of the actual conversion factor value of relative displacement, max, % ±5
Relative vibration displacement signal phase measurement range, degrees 0–360⁶
Maximum permissible phase measurement error of the relative vibration displacement signal, max, degrees ±3
Technological gap¹ ST between the eddy-current probe tip and the monitored surface, mm 1.0
Initial setting gap⁷ Su according to LCD indication readings, mm 2.0 ± 0.25
LCD information refresh time, max, s 0.5
Load resistance for 4–20 mA output signal, max, Ω 500
Output analog voltage signal range, V 0–3
Number of discrete (logic) outputs 5
Output discrete signals of the module:  
– DC voltage, max, V 12
– Current, max, A 1
Output type Open collector
Digital communication interface types RS485 (ModBus RTU)
Degree of protection:  
– Primary measuring transducer (PMT) IP67
– Measuring converter (MC) IP20
Dimensions:  
– PMT diameter; body length without stem, mm 18; 55
– MC height × width × depth, mm 114.5 × 17.5 × 99
Weight:  
– PMT without cable, max, g 175
– MC, max, g 125
  1. Measurement range with standardized metrological characteristics. The actual measurement range is from 10 µm to 5 mm.

  2. The maximum upper measurement limit of the relative vibration displacement peak-to-peak value together with relative displacement shall not exceed 4 mm.

  3. Frequency measurement range with standardized metrological characteristics. The actual frequency measurement range of the relative vibration displacement peak-to-peak value is from 0.05 Hz to 1500 Hz.

  4. Manufacturing with a different reference frequency value is available upon Customer request.

  5. The DC component of the output analog voltage signal is proportional to the relative displacement, while the AC component is proportional to the relative vibration displacement.

  6. Amplitudes and phases of harmonic components of vibration displacement are measured only when a keyphasor signal is applied to the corresponding input of the measuring converter (MC).

  7. Initial setting gap between the tip of the primary measuring transducer (PMT) and the monitored surface:
    S₀ = ST + Su.

Operating conditions for the PP-IP primary measuring transducer (PMT):

  • ambient temperature (air, water vapor, oil vapor): from −30 °C to +100 °C (short-term up to +120 °C);

  • electromagnetic field strength: up to 400 A/m;

  • relative air humidity: up to 98% at +35 °C; moisture condensation on the surface of the primary measuring transducer is permissible;

  • atmospheric pressure: from 84 kPa to 106.7 kPa.

Operating conditions for the FP-IP measuring converter (MC):

  • ambient air temperature: from +5 °C to +60 °C;

  • electromagnetic field strength: up to 100 A/m;

  • relative air humidity: up to 80% at +25 °C; moisture condensation is not permitted;

  • atmospheric pressure: from 84 kPa to 106.7 kPa.

Service life of the IDVP.01 Vibration Monitoring Module (VMM): 10 years from the date of delivery to the Customer.

Warranty operating period of the IDVP.01 Vibration Monitoring Module (VMM): 24 months from the date of commissioning.

Warranty storage period of the IDVP.01 Vibration Monitoring Module (VMM): 36 months from the date of purchase.

Installation of the PP-IP Primary Measuring Transducer for Rotor Vibration Displacement Monitoring